Supported Images¶
BayMorph opens any two-dimensional FITS image whose pixel values are linear
in flux. For the families of products on this page, a convention written
from their documentation tells BayMorph what their keywords mean; for any
other image, BayMorph reads the keywords of the FITS standard. Whatever the
header does not establish is never used, and you declare it in
data.calibration. Opening an Image shows how to see
what BayMorph has read, and how to declare the rest.
What BayMorph uses from a header¶
| Quantity | Used for | Without a usable value |
|---|---|---|
| Pixel scale, from the celestial WCS | the lengths that the advisor proposes, 0.1 to 120 arcsec; a working region in arcsec; a target in RA and Dec | the proposed lengths keep their default ranges in pixels; declare data.pixel_scale for a region in arcsec |
| Zeropoint | the flux priors that the advisor proposes, magnitudes 8 to 30 | the flux priors that need no zeropoint, from the sky and the PSF |
| Image unit | whether a zeropoint can be derived; a declared unit that differs from the one in the header sets aside the values that the header gives in the units of the image, such as the saturation level | the zeropoints that need it are not used |
| Saturation level, in the units of the image | half of it is the brightest star the advisor accepts for the PSF | the default ceiling, 80000, unless you set --psf-max-peak |
| Sky level subtracted before BayMorph, gain | where the effective gain of the noise model may come from; see Sky and Noise | the effective gain comes from the sky of the image, or you declare it |
| FWHM of the PSF | a Gaussian PSF requested without its FWHM | give --gaussian-fwhm-pixels |
| Telescope, instrument, detector, filter, dates of the observation | a request to a calibration service | no request |
The exposure time, and whether the image was combined or resampled, also enter the effective gain that the advisor proposes from the gain of the detector. Every quantity is recorded in the reports.
Every image¶
The FITS standard and the common keyword dictionaries apply to every header, and the conventions below take precedence where they read the same quantity.
| Quantity | Keyword | Read as |
|---|---|---|
| Telescope, instrument, filter | TELESCOP, INSTRUME, FILTER |
texts |
| Image unit | BUNIT |
the unit of the pixel values |
| Exposure time | EXPTIME |
seconds |
| Total exposure time | TEXPTIME |
seconds, when the comment of the card says so |
| Gain | GAIN |
electrons per ADU |
| Saturation level | SATURATE, or its synonym SATLEVEL |
the units of the image |
| FWHM of the PSF | FWHM |
arcsec or pixels, as FWHMUNIT, SEEUNIT or the comment of the card states |
| Zeropoint | PHOTZP |
ambiguous: outside the conventions that define it, its meaning is not established |
| Background level | BKGMED |
ambiguous: it has no generally documented meaning |
The pixel scale comes from the celestial WCS, as the mean of its projected scales along the two axes.
Product families¶
Each family is recognized by a keyword of its header. A product that no family recognizes is read through the keywords of every image.
Ground-based surveys and pipelines¶
| Products | Recognized by | BayMorph reads | You declare |
|---|---|---|---|
| ESO science data products (Phase 3) | PRODCATG |
the zeropoint PHOTZP, with mag = −2.5 log10(data) + PHOTZP, its error PHOTZPER and its system PHOTSYS; EXPTIME, the total integration time per pixel; TEXPTIME; NCOMBINE; ABMAGLIM; the FWHM PSF_FWHM in arcsec |
|
| ESO raw frames | a keyword that starts with ESO DET |
the read noise of the first output, in electrons, and the filter | the gain, when you need it: the ESO detector manual warns that its two keywords have been confused, so the direction of the conversion is not established |
| Coadds of the VST-Tube pipeline | PROCSOFT starting with VST-tube |
the zeropoint PHOTZP, with mag = −2.5 log10(ADU) + PHOTZP as its comment defines it, its error and its system; NCOMBINE; TEXPTIME; the subtracted sky level BKGMED, in the units of the coadd; the astrometric error |
the saturation level, when you need it: its comment gives ADU, while a coadd may be in ADU per second; the FWHM, whose unit no document of the pipeline states |
| Coadds written by SWarp | SOFTNAME = 'SWarp' |
the equivalent gain of the coadd, GAIN, and its saturation level, SATURATE |
|
| SDSS corrected frames | NMGY |
a zeropoint of 22.5 for pixels in nanomaggies, on the AB system, with the percent-level offsets of the SDSS calibration | the gain, when you need it: SDSS tabulates it by camera column and filter instead of writing it in the header |
| Coadds of the Legacy Surveys | LEGPIPEV |
a zeropoint of 22.5 for pixels in nanomaggies, without a photometric system: the optical bands are AB and the WISE bands Vega | |
| DECam images of the NOIRLab Community Pipeline | INSTRUME = 'DECam' |
the zeropoint MAGZERO for pixel values in ADU |
the detector, with data.hdu, in a file with one extension per detector; the zeropoint of an image in ADU per second, for which the pipeline writes MAGZPT; the saturation level, when you need it: SATURATA and SATURATB give the two amplifiers in ADU before the calibration of the image |
Images of hscPipe that record FLUXMAG0 |
FLUXMAG0 |
the zeropoint 2.5 log10(FLUXMAG0) |
|
| Pan-STARRS1 stacks | BSOFTEN |
the encoding of the pixels, compressed through asinh when BOFFSET is present too, and otherwise not established; BayMorph refuses both |
use the FITS cutouts of the PS1 image cutout service, which are linear |
| Cutouts linearized by astrocut | the HISTORY card of the conversion to linear flux |
linear pixels, although BSOFTEN and BOFFSET remain in the header |
From hscPipe 7 on, the header of a coadd records no FLUXMAG0: the manual
gives 27.0 mag for pixels in ADU, off by a few percent through the aperture
correction, and the zeropoint must be declared.
Space telescopes¶
| Products | Recognized by | BayMorph reads | You declare |
|---|---|---|---|
| HST images | TELESCOP = 'HST' |
the detector DETECTOR; the start and end of the observation, EXPSTART and EXPEND, as Modified Julian Dates; the filter from FILTER, or for ACS from its two filter wheels FILTER1 and FILTER2, leaving out a CLEAR element; the AB zeropoint −2.5 log10(PHOTFLAM) − 5 log10(PHOTPLAM) − 2.408 of a drizzled product (FILENAME with _dr) in electrons per second |
the zeropoint of any other product: flt and flc exposures need the pixel area map first |
| HST images drizzled to count rates | D001OUUN = 'cps' |
the unit, electrons per second, when BUNIT starts with ELECTRONS, whatever BUNIT says of the output; the AB zeropoint from PHOTFLAM and PHOTPLAM, also when FILENAME names an input exposure |
the zeropoint when PHOTFLAM is 0, which means that the pipeline did not compute it; the unit when BUNIT does not name electrons, since the counts may then be DN |
| Hubble eXtreme Deep Field mosaics | XDFVER |
the AB zeropoint of the release for the filter, for pixels in electrons per second: F435W 25.68, F606W 26.51, F775W 25.69, F814W 25.94, F850LP 24.87, F105W 26.27, F125W 26.23, F140W 26.45, F160W 25.94; the release does not correct the drift of the ACS zeropoints, of order one percent, over the years it combines | |
| HST/ACS Coma Cluster Treasury Survey images | FILENAME with _ivm_drz_cl, from program 10861 |
the AB zeropoint of the survey for pixels in electrons per second, F475W 26.068 and F814W 25.937, in place of the zeropoint of PHOTFLAM, which some of these headers give as 0 |
|
| JWST images | TELESCOP = 'JWST' |
the AB zeropoint −2.5 log10(10^6 PIXAR_SR / 3631) of a resampled image (FILENAME with _i2d) in MJy/sr; not of a cal image, whose pixel area varies across the detector |
|
| Mosaics of grizli, such as those of the DAWN JWST Archive | GRIZLIV |
the AB zeropoint −2.5 log10(PHOTFNU / 3631), 28.9 for pixels of 10 nJy; ZP, OPHOTFNU and PIXAR_SR describe the original unit and the native pixel of the inputs, and are not used |
For a drizzled ACS image of the WFC or HRC detector in electrons per second whose header gives no usable zeropoint, and for which you declare none, the observation advisor asks the ACS Zeropoint Calculator of STScI for the zeropoint of its detector, filter and dates, unless you keep it offline; see Writing a Configuration.
When conventions disagree¶
When two conventions read the same quantity, the more specific one decides,
a product before its instrument and an instrument before the FITS standard,
and BayMorph compares its value with the others. Two values that disagree
make the quantity conflicting until you declare it; two zeropoints agree
when they differ by at most 0.001 mag. A convention whose documentation
corrects another overrides it instead, and the header report records the
value it overrode: the drizzle rule overrides BUNIT, the zeropoints of the
XDF and of the Coma survey override the one derived from PHOTFLAM, and
astrocut overrides the encoding of the Pan-STARRS stack it linearized.